Analysis of Powerwall Battery Retention - Part 3

Ziga Mahkovec, Netzero Labs
Oct 19, 2026

Introduction

This is Part 3 of the Powerwall battery retention analysis. For an introduction, methodology, and earlier datasets, see Part 1 and Part 2.

This update includes:

Methodology Changes

The plots follow the same conventions as Parts 1 and 2: manufacturing date on the X axis (reversed, newest units on the left), nominal full-pack energy on the Y axis, and a small amount of random noise to prevent identification of individual batteries.

New in this part, each part-number plot carries a trend line showing the median capacity by manufacturing date.

The Powerwall 3 data now include Expansion packs (part number 1807000), which were not part of the Part 2 dataset.

Powerwall 2 Update

The updated scatter plot, color-coded by part number, now includes a trend line. The trend line excludes the 2018-2020 outlier cluster (part number 2012170, orange points at the bottom, discussed in Part 1), since its cause is not related to normal degradation, as well as the post-2024 replacement units discussed in Part 2. It therefore describes regular production only. Powerwall 2 production ended in late 2024.

The trend line makes the shape from Part 1 explicit:

Median capacity by age, excluding the outlier cluster and replacement units:

AgeMedian capacityBelow 13.5 kWhBelow 12 kWh
1-2 years14.05 kWh6%0%
2-4 years13.71 kWh38%1%
4-6 years13.25 kWh64%2%
6-8 years12.79 kWh90%3%
8-10 years12.82 kWh83%5%

Battery Retention by Discharged Energy

The color scale runs from 0 MWh/year (purple) to 7 MWh/year (yellow) of average discharged energy. 5 MWh/year corresponds to a full 13.5 kWh discharge every day.

The utilization gradient is clear. Among units older than 3 years (excluding the outlier cluster), the median capacity by average yearly discharge is:

Average dischargeMedian capacity
Under 1 MWh/year14.04 kWh
1-2 MWh/year13.50 kWh
2-3 MWh/year13.12 kWh
3-4 MWh/year12.86 kWh
Over 4 MWh/year12.79 kWh

Units that barely cycle, typically those with the backup reserve set to 100%, retain almost their full initial capacity after more than 3 years.

Powerwall 3 Update

The Powerwall 3 dataset has grown substantially, and the oldest units are now over 3 years old. The Y axis is narrower than in the Powerwall 2 plots to spread out the points, so the same capacity loss looks steeper here.

Observations:

AgeMedian capacityBelow 13.5 kWh
0-1 years14.38 kWh0%
1-2 years14.29 kWh5%
2-3 years14.03 kWh16%

Battery Retention by Discharged Energy

This is the first utilization plot for Powerwall 3. The color scale runs from 0 to 8 MWh/year.

The same utilization gradient appears, on a smaller scale. Among units older than 1.5 years:

Average dischargeMedian capacity
Under 1 MWh/year14.38 kWh
1-2 MWh/year14.29 kWh
2-3 MWh/year14.12 kWh
3-4 MWh/year13.99 kWh
Over 4 MWh/year13.95 kWh

Lightly used units have lost essentially nothing, and heavily cycled units about 0.45 kWh. Powerwall 3 units are also cycled harder: the median unit in this age range discharges 2.7 MWh/year, compared with 2 MWh/year for Powerwall 2 units older than 3 years.

Powerwall 2 vs Powerwall 3

With three years of Powerwall 3 data, the two generations can be compared at matching ages. Powerwall 3 uses lithium iron phosphate (LFP) cells, which are expected to tolerate more cycles than the nickel-manganese-cobalt (NMC) cells in Powerwall 2.

AgePowerwall 2 medianPowerwall 3 medianPowerwall 2 below 13.5 kWhPowerwall 3 below 13.5 kWh
1.5-2 years14.05 kWh14.16 kWh5%9%
2-2.5 years14.07 kWh14.03 kWh13%14%
2.5-3 years13.61 kWh13.75 kWh41%29%

Observations:

Conclusions

Nine years after the first Powerwall 2 units were built, the picture is stable: units lose about 1.2 kWh over their first five years, then hold steady near 12.8 kWh. Capacity loss tracks utilization closely, and lightly cycled units retain almost all of their initial capacity. Outside the 2018-2020 outlier cluster, units below the warranty threshold remain rare.

Powerwall 3 starts higher and more consistent, holds its capacity for the first year, and then begins to decline at a rate that, so far, is comparable to Powerwall 2 at the same age. The oldest Powerwall 3 units are still young by warranty standards, and we will continue to track them.

Contact

For questions or comments contact feedback@netzero.energy.